    Brand Name : ZUN
    Model Number : SG600-2S
    Certification : CE IEC
    Price : 70usd to 200usd
    Payment Terms : T/T
    Supply Ability : 5000pcs per month
    Delivery Time : 3-5 days
    • Product Details
    • Company Profile

    ZUN SG600 Hybrid Solar Pump Inverter DC AC input With Dry run protection

    ZUN sg600 solar pump inverter MPPT for AC pumps, DC pump inverter hybrid type solar pump drive


    The SG600 series solar pump inverter is a low voltage AC drive of 0.3 to 400KW above rating designed to operate with energy drawn from solar panel or photovoltaic cells (PV).

    The inverter is customized to operate in dual supply mode (AC and DC), so the grid connected supply is used in the absence of energy from PV cells. This inverters functions with the latest in technology maximum power point tracking (MPPT) algorithm to derive maximum power from the PV cells at any instant.

    • Maximum power point tracking (MPPT) with fast response speed and stable operation efficiency > 99.6%;
    • High speed running when sunlight radiation is good, frequency reduce fast when sunlight is become weak, stop running when output frequency lower lower limit frequency setting.
    • Suits for most 3 phase AC pumps and AC PMSM high efficiency pumps.
    • The working voltage of solar panel can set by manual or MPPT automatically tracking
    • Compatible with dual power input, AC grid and DC power supply input.
    • Built in automatic sleep-wake up function, start by timer is option.
    • Dry run (under load ) protection
    • Motor maximum current protection
    • Low input power protection
    • Lowest stop frequency protection
    • The PQ (power/flow) performance curve enables calculating the flow output from the pump
    • Digital control for fully automatic operation, data storage and protective functions
    • Intelligent power module (IPM) for the main circuit
    • LED display operating panel and support remote control
    • Low water probe sensor, and water level control function
    • Strong lightning protection
    • Easy operation and CVT auto detection function
    • GPRS function is option for remote start and stop, remote parameters setting.
    • Timer card is availalbe
    • LCD is available
    • Both DC and AC input connection is available

    Solar pump inverter models and specification

    SNModelsRate currentOutput voltage ( 3PH VAC)Applicable for pumpsMPPT voltage (VDC)
    Mini type 2S series : 90/150 to 450 VDC or 220VAC input,Vmp 310V, Voc 380V
    1SG600-0K7GB-2S-M3.8A0-220VAC0.75KW260 to 375
    2SG600-1K5GB-2S-M7A0-220VAC1.5KW260 to 375
    3SG600-2K2GB-2S-M10A0-220VAC2.2kw260 to 375
    4SG600-4K0GB-2S17A0-220VAC4.0KW260 to 375
    General type: 4T, 250/350 to 800 VDC or 380VAC input, Vmp520, Voc650
    1SG600-0K7GB-4T2.3A0-380V0.75KW486 to 750
    2SG600-1K5GB-4T3.8A0-380V1.5KW486 to 750
    3SG600-2K2GB-4T5.1A0-380V2.2KW486 to 750
    4SG600-4K0GB-4T10A0-380V4.0KW486 to 750
    5SG600-5K5GB-4T13A0-380V5.5KW486 to 750
    6SG600-7K5GB-4T17A0-380V7.5KW486 to 750
    7SG600-011GB-4T25A0-380V11KW486 to 750
    8SG600-015GB-4T32A0-380V15KW486 to 750
    9SG600-018GB-4T37A0-380V18KW486 to 750
    10SG600-022GB-4T45A0-380V22KW486 to 750
    11SG600-030G-4T60A0-380V30KW486 to 750
    12SG600-037G-4T75A0-380V37KW486 to 750
    13SG600-045G-4T91A0-380V45KW486 to 750
    14SG600-055G-4T110A0-380V55KW486 to 750
    15SG600-075G-4T150A0-380V75KW486 to 750
    16SG600-090G-4T180A0-380V90KW486 to 750
    17SG600-110G-4T220A0-380V110KW486 to 750
    18SG600-132G-4T260A0-380V132KW486 to 750
    19SG600-160G-4T320A0-380V160kw486 to 750
    20SG600-185G-4T377A0-380V185kw486 to 750
    21SG600-200G-4T426A0-380V200kw486 to 750
    22SG600-220G-4T465A0-380V220kw486 to 750
    23SG600-250G-4T465A0-380V250kw486 to 750
    24SG600-280G-4T520A0-380V280kw486 to 750
    25SG600-315G-4T585A0-380V315kw486 to 750
    26SG600-355G-4T650A0-380V355kw486 to 750
    27SG600-400G-4T725A0-380V400kw486 to 750

    Solar pump inverter technical specification


    **Solar pump inverter specification when PE-00=1&2
    Recommended MPPT voltage range

    Vmp 131 to 350 VDC for 1s 3 phase 110VAC pumps

    Vmp 260 to 355VDC for 2S 3 phase 220VAc pumps

    Vmp 486 to 650 VDC for 4T 3 phase 380VAc pums

    Recommended input Voc and Vmpp voltage

    Voc 180(VDC), Vmpp 155(VDC) for 1S model or 110V AC pumps

    Voc 380(VDC), Vmpp 310(VDC) for 2S model or 220V AC pumps

    Voc 650(VDC), Vmpp 520(VDC) for 4T model or 380V AC pumps

    Voc 820(VDC), Vmpp 676(VDC) for 5T model or 480V AC pumps

    Motor typeControl for permanent magnet synchronous motor and asynchronous motor pumps.
    Rated output voltage1/3-Phase,110V/160V/220V. 3-phase, 220V/380V/460V
    Output frequency range0~maximum frequency 600Hz.
    MPPT efficiencyAbove 99.6%,
    Ambient temperature range

    G-type for submersible pumps, 150% rated current for 60s, 180% rated current for 2s .

    P type for general pumps, 120% rated current for 60s, 150% rated current for 2s

    Solar pump control special performanceMPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum current protection, flow calculating, energy generated calculating and water tank level detected
    Protection functionPhase loss protection, phase short circuit protection, ground to phase circuit protection , input and output short circuit protection. Stall protection, lightning protection
    Protection degreeIP20, Air force cooling
    Running modeMPPT or CVT
    AltitudeBelow 1000m; above 1000m, derated 1% for every additional 100m.
    Enhanced version of AC driveCE, Design based on vector control motor AC drive, more specification please refer to S600 or S600 vector control drive operation manual
    Technical specification of variable frequency inverter when PE00=0(solar pump disable)
    voltage, frequency1 phase 220V, 3 phase, 220V,380V, 660V, 0-50/60Hz
    Control mode0: VF control ; 1: Open loop vector control mode 2: Close loop vector control mode
    Maximum frequency0-320Hz in vector control mode, 0~3200Hz in VF control mode
    Multiple-functionsPID Control, Carrier Frequency Adjustable, Current Limiter, Speed Search, Momentary Power Loss Restart,16 Step Speed (Max), 3-Wire connection, Slip Compensation, Frequency Jump, DC braking, Upper/Lower Frequency, Torque control, Compatible for PMSM and IM, built in RS485, counting, fault information checking, fully fault protection function, frequency combination reference.

    SG600 solar pump inverter solar pump parameters

    PE Solar control purpose parameters.
    PE-00Solar pump control mod`e

    0:Disable of solar pump control
    1: Enable (Algorithm-1, High fficiency )

    2: Enable (Algorithm-2, High stability )

    1
    PE-01Solar pump control mode option

    1 Bit: Vmpp mode selecting

    0: Vmp set by PE-02 manually (CVT)

    1: MPPT automatically

    Ten: Voc ( open loop voltage of PV ) detect mode

    0: Voc set by PE-03 manually

    1: Voc detect automatically

    Hundred: Auto running by keypad

    0: Disable

    1: Auto start/stop in keypad control mode. Inverter will automatically start when power on after 5 seconds only on keypad control mode.

    H.001
    PE-02CVT voltage set by manual0 -100%80%
    PE-03Voc ( open loop voltage ) set manually0.0V-1000.0V

    650V/

    380V

    PE-04DC bus voltage stability Proportional gain0.0% - 999.9%100.0%
    PE-05DC bus voltage stability Integral gain0.0% - 999.9%100.0%
    PE-06DC bus voltage stability differential gain0.0% - 999.9%5%
    PE-07Initial point of fast frequency drop0.0 - 100.0%5.0%
    PE-08Stop point of fast frequency drop0.0 - 100.0%50.0%
    PE-09Weak magnetic limit multiples0.0- 9.91.2
    PE-10Mppt search upper limit voltage0.0% - 100.0%90%
    PE-11Mppt search lower limit voltage0.0% - 100.0%75%
    PE-12MPPT search gain0% - 500%100%
    PE-13MPPT search interval0.0 - 10.0sec2.0sec

    SG600 solar pump inverter installation steps.

    Wiring and commissioning
    1. Connect DC power supply to P to P- (N) ( DC power supply also can wire to R, T , no need consider to polarity connection)
    2. Check Voc input, if correct, switch one power.
    3. Set motor parameters as pumps nameplate.
    4. Confirmed the solar pump control mode and MPPT function mode. (PE-000=1)
    5. Trail running with press RUN button to check running direction.
    6. Set dry run function, lowest stop frequency, maximum current, flow PQ curve if need.
    If need auto start and stop, you can select to terminals control with switch on X1 to COM.
    a). DI1 and COM, (P4.00=1, forward running)
    b), DI2 and COM, (P4.01=2, reverse running)
    c), DI3 and COM, ( P4.02=53, solar control mode disable )
    d), DI4 and COM, ( P4.03=51, digital signal of water leveling detect 1)